Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants

Reagent Type Residual Chlorine Sensor

0-10 mg/L Measuring Range Chlorine Analyzer

100-240 V DC Power Supply Water Quality Sensor

Hàng hiệu:

Yokogawa

Số mô hình:

RC800D

Liên hệ với chúng tôi
Yêu cầu Đặt giá
Chi tiết sản phẩm
đối tượng đo:
Clo tự do hoặc clo dư (tổng clo) trong nước
Hệ thống đo lường:
Phương pháp amperometric (phương pháp phân cực) sử dụng điện cực xoay
Phạm vi đo lường:
0-10 mg/l
Cung cấp điện:
100 đến 240 V dc, 50/60 Hz
Làm nổi bật:

Reagent Type Residual Chlorine Sensor

,

0-10 mg/L Measuring Range Chlorine Analyzer

,

100-240 V DC Power Supply Water Quality Sensor

Điều khoản thanh toán và vận chuyển
Số lượng đặt hàng tối thiểu
1pcs
chi tiết đóng gói
Mỗi đơn vị có hộp riêng lẻ và tất cả các hộp được đóng gói trong các gói tiêu chuẩn hoặc yêu cầu của
Thời gian giao hàng
5-8 ngày làm việc
Điều khoản thanh toán
L/C, D/A, D/P, T/T, Liên minh phương Tây, Moneygram
Khả năng cung cấp
1000 mảnh/mảnh mỗi tuần có thể thương lượng
Mô tả sản phẩm
Reagent Type Residual Chlorine Sensor Unit RC800D
Reliable Chlorine Measurements in Water Treatment Plants Since 1959

No.1 Process analyzer supplier to Japanese market*

"Reliable Chlorine monitoring and minimize Chlorine injection"

"Continuous automatic cleaning and achieved less maintenance time"

"Maintenance remotely and reduce maintenance time"

Many of our customers face these challenges - Yokogawa Chlorine Analyzers resolve them.

The RC800D residual chlorine analyzer employs a polarographic system that uses rotating platinum electrodes to provide a continuous online measurement of residual chlorine concentration. It is possible to separate residual chlorine (free chlorine + combined-chlorine) from free chlorine for measurements by appropriate use of reagents.

The RC800D is suitable for various water condition measurements and gives you a stable and high-quality measurement thanks to the rotation electrodes and superior reagent pump.

The RC800D is intended for water distribution measurements at pumping stations, water delivery points, schools, and public facilities.

*Based on a Yokogawa survey in 2019

Key Features
  • Amperometric measurement of free chlorine or total chlorine (polarographic method)
  • Measure Free chlorine or residual chlorine (total chlorine) continuously in water
  • Unique rotation electrode method keeps sensor clean and reduces maintenance cycle
  • Superior reagent pump realizes stable measurement regardless of sample conditions
  • Easy maintenance structure, modularized motor unit, and diagnostics functions strongly support regular maintenance
  • Remote wash and calibration functions are available
  • RC800D is equipped with Manual calibration and Auto Calibration, 2 points correction, Basic (reference) sensitivity calibration, and circuit open Zero calibration
  • Remote range switching is available
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 0
RC800D Left Side View
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 1
RC800D Easy to Use Touch Screen Display
Structure
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 2
TC8000D Structure Diagram
Applications
Each process at treatment plant: from reservoir to treated water, distribution system
  • Water Purification Treatment
  • Stabilization
  • Flocculation
  • Settling Basins
  • Chlorination
  • Clean water reservoir
  • Distributing pump
  • Distribution tank & Piping
Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants 3
Use Case Diagram
Specifications
Measured Object Free chlorine or residual chlorine (total chlorine) in water
Measuring System Amperometric method (Polarographic method) using rotating electrode
Measuring Range 0-10 mg/L
Sample Conditions Temperature: 0 to 50°C (Temperature compensation is effective within 0 to 40°C)
pH: 3 to 9
Flow Rate: 1 to 4 L/min, for pure water or municipal water application.
5 to 10 L/min, for raw water or sea water application.
10 to 20 L/min, for secondary sewage treatment application.
Pressure 20 to 500 kPa
Power Supply 100 to 240 V DC, 50/60 Hz
Digital Communication Modbus TCP/IP, Modbus RTU
Installation Indoor (Outdoor use requires protection against rain. Direct sunlight must be avoided.)
Performance
Linearity ±3% of reading or ±0.03 mg/L whichever is greater
Repeatability ±1% of reading or ±0.01 mg/L whichever is greater