logo
Nhà > các sản phẩm > Cảm biến chất lượng nước >
KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2%

KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2%

Dissolved Oxygen Sensor RS485 Interface

Dissolved Oxygen Sensor Anti Interference

Place of Origin:

CHINA

Hàng hiệu:

kacise

Chứng nhận:

CE

Model Number:

KFDO601

Liên hệ với chúng tôi
Yêu cầu Đặt giá
Chi tiết sản phẩm
Measuring principle:
Fluorescence method
Range ability:
0~20mg/L (0 ≤ 200% saturation)
Resolution ratio:
0.01mg/L,0.1℃
Precision:
±2%F.S.,±0.5℃
Temperature compensation:
Automatic temperature compensation(Pt1000)
Output mode:
RS-485 bus, Modbus-RTU protocol
Làm nổi bật:

Dissolved Oxygen Sensor RS485 Interface

,

Dissolved Oxygen Sensor Anti Interference

Điều khoản thanh toán và vận chuyển
Minimum Order Quantity
0-100
Giá bán
$0-$2000
Packaging Details
Common package or custom package
Delivery Time
3-10days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
100
Sản phẩm liên quan
Liên hệ với chúng tôi
86--17719566736
Liên hệ ngay bây giờ
Mô tả sản phẩm

KFDO601 Online Fluorescence Dissolved Oxygen No Electrolyte Is Required And Will Not Be Polarized No Oxygen Consumption

 

 

1.Dissolved oxygen measurement applications

 

  • Food and Beverages
  • The pharmaceutical
  • Energy and electricity
  • education
  • The government
  • water
  • Waste water management

 

2.the Difference of Polarographic probe and optical probe

 

 

  Polarographic probe optical probe
maintence Replace the electrolyte approximately every 2 months and polish the cathode as needed to clean the probe Clean probe, cover and optical window as needed
storage Stored in a wet calibration sleeve;For long-term storage, remove the film cover and store in a dry place Store in a wet calibration sleeve
film Replace approximately every 2 months as needed no
solution Replace approximately every 2 months as needed no
Need to preheat (30-60 minutes) if only connected to the meter  
stir need unnecessary
disturb Ozone, sulfides, sulfur dioxide, nitrous oxide and carbon monoxide  

 

3.Feature

 

  • No electrolyte is required and will not be polarized.
  • No oxygen consumption, not affected by flow rate.
  • Built-in temperature sensor, automatic temperature compensation.
  • Free from interference by chemicals such as sulfides
  • Small drift, rapid reaction, more accurate measurement.
  • Long service cycle, lower cost of use.
  • Simple replacement of fluorescent cap.
  • Rs-485 interface, Modbus/RTU protocol.
  • Low power consumption,anti-interference.

 

4.Technical Specifications

 

Model KFDO601
Measuring principle Fluorescence method
Range ability 0~20mg/L (0 ≤ 200% saturation)
Resolution ratio 0.01mg/L,0.1℃
Precision ±2%F.S.,±0.5℃
Temperature compensation Automatic temperature compensation(Pt1000)
Output mode RS-485 bus, Modbus-RTU protocol
Working conditions 0~45℃,<0.2MPa
Storage temperature -5~65℃
Installation mode Immersion mounting
Cable length 5 meters, other lengths customizable
Power dissipation <0.3W@12V
Source 12~24VDC ±10%
levels of protection IP68
Calibration Two-point calibration
Fluorescent cap life Guaranteed use for one year (under normal use)
Sensor shell material POM and 316L stainless steel
 

5.Dimensional Drawing

KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2% 0

Note:The sensor connector is m16-5 core waterproof connector male.

 

6.Installation

KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2% 1

 

 

The sensor shall be installed fixedly below the liquid level. The installation and use shall avoid collision or scraping against the surface of the fluorescent film head. The fluorescent film head part shall avoid being attached by the bottom sediment.Remove the rubber cover when use.

 

Contact Us

 

Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China
KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2% 2

 

 

 

Gửi yêu cầu của bạn trực tiếp đến chúng tôi

Chính sách bảo mật Trung Quốc Chất lượng tốt Máy đo nồng độ chất lỏng Nhà cung cấp. 2018-2025 Xi'an Kacise Optronics Co.,Ltd. Tất cả các quyền được bảo lưu.